Specifications:
- Linearity: +/-.5%
- Premium Linearity: +/-.25% (over a specified range)
- Repeatability: +/-.05%
- Premium Repeatability: +/-.02% (over a specified range)
- Temperature: -450°F to +450°F std., +1000°F available
- Materials: Precision Turbine Flowmeters are constructed of 300
and 400 series stainless steel. A variety of other materials are available to satisfy most
applications including CPVC for corrosive applications (See Bulletin 5003)
- Electrical Output: A minimum of 30 mV peak to peak at the
minimum repeatable flow
- Pressure Drop: 4 psi at nominal rated flow range
- End Fittings: Include AN series 37°, flare tube (MS-33656),
NPT, and ANSI flanges. Other End Fittings available on request
- Operating Pressure: Accommodates unlimited pressures depending
on end fittings
- Calibration: Precision Turbine Flowmeters furnished with
standard fluid calibration. Special calibrations available
- Flow Ranges: From .25 to 12,000 GPM
- specifications based on ball bearings. Altering bearing
selection may alter specification performance, consult factory
NOTE: for specific
examples, consult factory
Liquid Sizing Chart
Gas Flowmeter Specifications
/ Sizing Guide
Information Needed for
Meter Selection |